Landscape Lighting Layout and Transformer Load Calculator
Count evenly spaced path fixtures and compare manufacturer fixture VA with an entered transformer allowance in two separate planning modes.
Use this result well
- Inputs that matter
- Path length, Chosen maximum spacing, Sources and assumptions, Group 1 fixture count, and 8 more
- Output to expect
- Path fixture spacing, Fixture VA and transformer load
- Check the units and required inputs before comparing results.
- Keep the assumptions with a copied result so you can reproduce the calculation later.
Related Tools
Tools you might need next
Compare 12, 10, 8 and 6 AWG cable using current, one-way length and conductor resistance. See when no candidate meets your entered voltage drop limit.
Build an installed quote, compare lifetime costs and calculate material packs. Separate payment-day cash from later reimbursements using your project records.
Estimate appliance kWh and cost by day, week, average month, current calendar month, and year, with an optional regional CO₂ factor.
Reference & details
How it works
Updated September 2026
How it works
Updated September 2026Path fixture spacing
Place a fixture at each endpoint of one straight path and distribute the remaining fixtures evenly without exceeding your chosen maximum spacing. This is geometry; lighting coverage depends on actual photometry, mounting, obstacles and night testing.
Intervals = ceiling(path length / maximum spacing); fixtures = intervals + 1; actual even spacing = path length / intervals.Fixture VA and transformer load
Total up to three fixture groups using manufacturer apparent-power ratings in VA. Compare the total with an entered transformer rating and its documented permitted load percentage. This does not choose cable size or certify a supply for a particular installation.
Total VA = Σ fixture count × rated fixture VA; allowed load = transformer VA × chosen permitted percentage; estimated RMS current = total VA / nominal secondary volts.Updated: September 2026
Example Scenarios
The built-in example supplies labeled assumptions. Replace them with your own records before making a decision.
→ 8 fixtures
The built-in example supplies labeled assumptions. Replace them with your own records before making a decision.
→ Within entered VA allowance
FAQ
About Landscape Lighting Layout and Transformer Load Calculator
Place a fixture at each endpoint of one straight path and distribute the remaining fixtures evenly without exceeding your chosen maximum spacing. This is geometry; lighting coverage depends on actual photometry, mounting, obstacles and night testing. Total up to three fixture groups using manufacturer apparent-power ratings in VA. Compare the total with an entered transformer rating and its documented permitted load percentage. This does not choose cable size or certify a supply for a particular installation.