Seasonal HVAC Electricity Cost Calculator
Estimate heating and cooling electricity from documented thermal loads, equivalent seasonal hours, seasonal efficiency ratings and an entered tariff.
Use this result well
- Inputs that matter
- Reference cooling load (Btu/h), Cooling equivalent full-load hours, Cooling seasonal rating (Btu/Wh), Reference heating load (Btu/h), and 4 more
- Output to expect
- Seasonal heating and cooling costs
- Check the units and required inputs before comparing results.
- Keep the assumptions with a copied result so you can reproduce the calculation later.
Related Tools
Tools you might need next
Compare the same entered heating demand using explicit equivalent full-load hours, seasonal heat-pump efficiency, furnace AFUE, tariffs and other annual costs.
Build an installed quote, compare lifetime costs and calculate material packs. Separate payment-day cash from later reimbursements using your project records.
Estimate appliance kWh and cost by day, week, average month, current calendar month, and year, with an optional regional CO₂ factor.
Reference & details
How it works
Updated September 2026
How it works
Updated September 2026Seasonal heating and cooling costs
Estimate electricity from entered reference thermal loads and equivalent full-load hours, divided by seasonal efficiency ratings in Btu/Wh. Equivalent hours represent total seasonal delivered energy divided by that reference load; they are not raw thermostat runtime or a local weather forecast.
Cooling kWh = cooling Btu/h × equivalent hours ÷ (SEER or SEER2 × 1000); heating kWh = heating Btu/h × equivalent hours ÷ (HSPF or HSPF2 × 1000); cost = kWh × tariff.Updated: September 2026
Example Scenarios
The built-in example supplies labeled assumptions. Replace them with your own records before making a decision.
→ $1,770.00
FAQ
About Seasonal HVAC Electricity Cost Calculator
Estimate electricity from entered reference thermal loads and equivalent full-load hours, divided by seasonal efficiency ratings in Btu/Wh. Equivalent hours represent total seasonal delivered energy divided by that reference load; they are not raw thermostat runtime or a local weather forecast.