Wind Energy: Period Factor and Power-Curve Bins
Calculate wind energy over explicit period hours from capacity factor, or integrate speed-duration bins with an actual curve and documented losses.
Use this result well
- Inputs that matter
- Reference capacity (kW), Entered period capacity factor (%), Period duration (h), Sources and assumptions, and 7 more
- Output to expect
- Energy from capacity and period factor, Power-curve energy from speed bins
- Check the units and required inputs before comparing results.
- Keep the assumptions with a copied result so you can reproduce the calculation later.
Related Tools
Tools you might need next
Calculate observed capacity factor over exact period hours, or integrate a Weibull wind distribution with an actual curve and explicit losses.
Value actual self-used and exported wind energy, then compare explicit dated cash flows, NPV and payback that remains recovered through the horizon.
Size battery energy for a supplied lull, or follow chronological wind, solar and load with SOC limits, unmet demand and required wind diversion.
Reference & details
How it works
Updated September 2026
How it works
Updated September 2026Energy from capacity and period factor
Translate an explicit reference capacity and capacity factor into energy over the stated period. Zero production is valid; the capacity factor must already represent the intended delivered-energy boundary.
Period kWh = reference kW × capacity factor/100 × period hours.Power-curve energy from speed bins
Calculate period energy from documented wind-speed duration bins and an electrical turbine curve. Include calm and cut-out periods, specify period coverage and apply each loss once.
Gross kWh = Σ P(speedᵢ) × hoursᵢ; net kWh = gross × availability × (1−additional loss).Updated: September 2026
Example Scenarios
Try this example to see the calculation, then enter actual documented values and preserve the measurement conditions. A failed or unresolved comparison is part of the record.
→ 10,980 kWh in the entered period
Try this example to see the calculation, then enter actual documented values and preserve the measurement conditions. A failed or unresolved comparison is part of the record.
→ 13,085.3 kWh from supplied bins
FAQ
About Wind Energy: Period Factor and Power-Curve Bins
Translate an explicit reference capacity and capacity factor into energy over the stated period. Zero production is valid; the capacity factor must already represent the intended delivered-energy boundary. Calculate period energy from documented wind-speed duration bins and an electrical turbine curve. Include calm and cut-out periods, specify period coverage and apply each loss once.