Panel Demand and Space Planner
Reconcile documented split-phase demand categories and per-leg current, then count actual panel spaces and circuits in a separate inventory.
Use this result well
- Inputs that matter
- Calculation method and edition, Line-to-line voltage (V), Service or feeder current limit per leg (A), Demand categories and leg allocation, and 5 more
- Output to expect
- Split-phase demand reconciliation, Panel space and circuit inventory
- Check the units and required inputs before comparing results.
- Keep the assumptions with a copied result so you can reproduce the calculation later.
Related Tools
Tools you might need next
Check configured EVSE AC current against ordinary circuit limits, then estimate charging energy and time using vehicle acceptance and efficiency.
Count unique planned AFCI and dual-function breakers from reviewed circuits, retaining approved alternative protection and unresolved decisions.
Compare copper and aluminum chart sizes using required ampacity, correction factors, terminal ratings and protection limits; save the full basis.
Reference & details
How it works
Updated September 2026
How it works
Updated September 2026Split-phase demand reconciliation
Reconcile a documented 120/240-type split-phase service or feeder calculation by load category and leg. Enter each category's connected VA, independently established demand percentage and separately required VA adder. Select the method with the authority reviewing the installation; no blanket 40% demand factor or automatic service size is supplied.
Category demand = connected VA × entered % / 100 + adder VA; L1/L2 current = allocated leg VA ÷ line-to-neutral voltage.Panel space and circuit inventory
Count physical panel spaces and supported circuit positions from an actual equipment schedule. Breaker pole count, occupied spaces and supported circuits are separate manufacturer-defined quantities, especially for tandem and quad devices.
Used spaces = Σ(quantity × spaces each); used circuits = Σ(quantity × circuits each).Updated: September 2026
Example Scenarios
Try the built-in example, then replace its source data with your actual documented values. Retain failed comparisons and unresolved decisions.
→ Entered leg currents fit the stated limit
Try the built-in example, then replace its source data with your actual documented values. Retain failed comparisons and unresolved decisions.
→ Counts fit the listed panel limits
FAQ
About Panel Demand and Space Planner
Reconcile a documented 120/240-type split-phase service or feeder calculation by load category and leg. Enter each category's connected VA, independently established demand percentage and separately required VA adder. Select the method with the authority reviewing the installation; no blanket 40% demand factor or automatic service size is supplied. Count physical panel spaces and supported circuit positions from an actual equipment schedule. Breaker pole count, occupied spaces and supported circuits are separate manufacturer-defined quantities, especially for tandem and quad devices.