Small Wind Power: Aerodynamics and Actual Curves
Calculate shaft and electrical wind power from explicit conditions, or interpolate an actual turbine curve with documented cut-in and cut-out limits.
Use this result well
- Inputs that matter
- Horizontal-axis rotor diameter (m), Wind speed at rotor (m/s), Air density (kg/m³), Shaft power coefficient Cp, and 5 more
- Output to expect
- Aerodynamic operating point, Electrical power-curve lookup
- Check the units and required inputs before comparing results.
- Keep the assumptions with a copied result so you can reproduce the calculation later.
Related Tools
Tools you might need next
Calculate wind energy over explicit period hours from capacity factor, or integrate speed-duration bins with an actual curve and documented losses.
Calculate observed capacity factor over exact period hours, or integrate a Weibull wind distribution with an actual curve and explicit losses.
Calculate circular horizontal-axis or straight vertical-axis rotor area, then compare two geometries on the same wind speed and density basis.
Reference & details
How it works
Updated September 2026
How it works
Updated September 2026Aerodynamic operating point
Calculate rotor-stream kinetic power, extracted shaft power and converted electrical power from the stated operating point. Keep a constant-Cp point estimate distinct from a turbine power curve or annual production.
Stream W = 0.5 × density × swept area × speed³; shaft W = stream W × Cp; electrical W = shaft W × conversion efficiency.Electrical power-curve lookup
Interpolate a documented turbine electrical power curve at an entered wind speed and enforce its explicit cut-in and cut-out range. Preserve the curve source and operating conditions.
Within the operating range, P(v) = P₁ + (P₂−P₁)(v−v₁)/(v₂−v₁); outside the range P = 0.Updated: September 2026
Example Scenarios
Try this example to see the calculation, then enter actual documented values and preserve the measurement conditions. A failed or unresolved comparison is part of the record.
→ 1.939619 kW electrical estimate
Try this example to see the calculation, then enter actual documented values and preserve the measurement conditions. A failed or unresolved comparison is part of the record.
→ 2.15 kW from the entered curve
FAQ
About Small Wind Power: Aerodynamics and Actual Curves
Calculate rotor-stream kinetic power, extracted shaft power and converted electrical power from the stated operating point. Keep a constant-Cp point estimate distinct from a turbine power curve or annual production. Interpolate a documented turbine electrical power curve at an entered wind speed and enforce its explicit cut-in and cut-out range. Preserve the curve source and operating conditions.