Receptacle Spacing and Coverage Calculator
Generate positions on actual eligible wall spans, then check measured receptacle coordinates for uncovered gaps using a documented reach rule.
Use this result well
- Inputs that matter
- Eligible spaces and spacing rule, Chosen maximum horizontal reach (ft), Continuous eligible spans, Sources and assumptions, and 1 more
- Output to expect
- Receptacle layout by eligible span, Check actual receptacle coverage
- Check the units and required inputs before comparing results.
- Keep the assumptions with a copied result so you can reproduce the calculation later.
Related Tools
Tools you might need next
Plan continuous cable cuts from a specified circuit route, actual slack and parallel cable counts, then allocate stock rolls and quoted cost.
Build an installed quote, compare lifetime costs and calculate material packs. Separate payment-day cash from later reimbursements using your project records.
Map actual GFCI devices and downstream outlets, record tests and expose unknown requirements without inventing circuit or device counts from rooms.
Reference & details
How it works
Updated September 2026
How it works
Updated September 2026Receptacle layout by eligible span
Create a centered minimum-count geometric layout on each supplied continuous eligible span. Distances follow the wall line and each span has two endpoints. Specify actual excluded openings as breaks instead of subtracting an assumed door width from total perimeter. Check furniture, access, mounting and placement restrictions on the real plan.
For each span, n = ceil(length / (2 × reach)); positions = length × (2j + 1) / (2n), j = 0…n−1.Check actual receptacle coverage
Check a measured or proposed set of receptacle coordinates on each eligible span against the chosen horizontal reach. Overlapping coverage is merged before uncovered lengths are counted. No coverage passes through a break between separate spans.
Each position x covers [max(0, x−reach), min(length, x+reach)]; merge intervals, then report all remaining gaps.Updated: September 2026
Example Scenarios
Try the built-in example, then replace its source data with your actual documented values. Retain failed comparisons and unresolved decisions.
→ 4 geometric receptacle positions
Try the built-in example, then replace its source data with your actual documented values. Retain failed comparisons and unresolved decisions.
→ 1 spans have uncovered gaps
FAQ
About Receptacle Spacing and Coverage Calculator
Create a centered minimum-count geometric layout on each supplied continuous eligible span. Distances follow the wall line and each span has two endpoints. Specify actual excluded openings as breaks instead of subtracting an assumed door width from total perimeter. Check furniture, access, mounting and placement restrictions on the real plan. Check a measured or proposed set of receptacle coordinates on each eligible span against the chosen horizontal reach. Overlapping coverage is merged before uncovered lengths are counted. No coverage passes through a break between separate spans.